30kw-400-hz-gen-set Image

30KW 400 HZ Gen Set

30 KW 400 HZ Gen Set. Ex- military unit. National Stock No. 6115-00-118-1248, 6115001181248, 6115 00 118 1248. 120 / 208, 240 / 416 VAC 3 phase 12 lead reconnectable, 400 hz @ 1800 RPM. 1329 total hrs on unit. Powered by Hercules D298ERX37 D3000 White D298ER White / Hercules 6 cyl diesel, Self contained. Offered…
SMID: 111-1602-534
Condition: Good
-Sold

onan-10kw-air-cooled-gen-set Image

Onan 10KW Air Cooled Gen Set

Onan 10 Kw Gen Set. Powered by Onan 4 cyl air cooled diesel. Military design, model no. MEP 003A. 120 / 240 VAC 1 phase, 120 / 208 3 phase, phase and voltage selector switch. 24 V starter and alternator. 60 hz. Weight, 1220 lbs. Dimensions, L 62", W 32", Ht 37". Fully self contained with fuel tank, or can be operated…
SMID: 112-2486-361
Condition: Good
-Sold

cummins-nhc-250-150kw-gen-set Image

Cummins NHC 250 150KW Gen Set

NSN: 6115-00-081-2036
Fermont model MB-15 diesel generator set. Cummins NHC 250 150 KW Gen Set. 12 lead reconnectable generator. 60 hz @ 1800 RPM. Test ran 3 years ago, generated electricity. In storage 3 years, engine turns over. As is. Dimensions 128x40x72, weight approx 7000 lbs.
NSN 6115000812036
SMID: 114-9278-637
Condition: As is
-Sold

100kw-cat-generator-set-3306t Image

100kW Cat Generator Set, 3306T

Caterpillar 3306 generator set, skid mounted radiator cooled. call for details rated 135 prime
SMID: 122-5575-432
Condition: Call
-Sold

400-hz-90-kva-protable-gpu Image

400 HZ 90 KVA Protable GPU

400 HZ 90 KVA Portable GPU, equivalent to Hobart 72kw
call for details
SMID: 122-5575-797
Condition: Call
-Sold

100-kw-genset-mep007b Image

100 KW Genset MEP007B

NSN: 6115-01-036-6374
100 KW Genset. Model MEP007B. Serial no. RZ00733. 3306-PCT Cat engine, Arrangement no. 5R363507, serial no. 49S00900. 12 lead re-connectasble with re-connect board. 3 phase, 50 - 60 hz. Missing starter, Oil Press and Temp Gauge. Available as is or re-furbished. NSN 6115010366374
SMID: 127-7415-095
Condition: Good
-Sold

john-deere-30kw-genset Image

John Deere 30kw Genset

John Deere 30 kw Genset. Powered by John Deere 4-276 engine. Lima generator end, part no. 3166-1188, serial no. ADIC4368-CJD. 12 lead re-connectable. 60 HZ @ 1800 RPM. Marine exhaust manifold, 12V starter and alternator. As pictured.
SMID: 127-9892-705
Condition: As is
-Sold

military-mep-806a-genset-60kw Image

Military MEP-806A Genset 60kw

NSN: 6115-01-274-7390
Military MEP-806A 60 KW Generator Set. Serial no. RZJ. 120/208, 240/416 VAC 3 phase. Mounted on 4 wheel trailer. As is, will part out. NSN 6115012747390
SMID: 132-2066-912
Condition: As is
-Sold

military-mep-806a-60-kw-genset Image

Military MEP-806A 60 KW Genset

NSN: 6115-01-274-7390
Military MEP-806A 60 KW Generator Set. 120/208, 240/416, 460/480 VAC 3 phase. Serial no. RZJ01277. 643 hours. Powered by John Deere 6059T diesel engine. 43 gallon fuel tank. Note burned wires going to current transformers, minor repair. Made by Libby Corp. NSN 6115012747390
SMID: 140-5018-472
Condition: Good
-Sold

onan-5kw-genset-model-mep002a Image

Onan 5KW Genset Model MEP002A

NSN: 6115-00-456-1044
Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. R232981. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 5492 hrs on unit. Unit turns over, does not run. Suspect bad injection pump. appears complete. Several available. NSN 6115004561044
SMID: 143-3867-441
Condition: As is
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

NSN: 6115-00-456-1044
Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Engine serial no. 1880764195. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 3498 hrs on unit. Unit turns over, appears complete. Several available. NSN 6115004561044
SMID: 143-3871-639
Condition: As is
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

NSN: 6115-00-456-1044
Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. KZ13731. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 226 hrs on unit. Unit turns over, appears complete. Several available. NSN 6115004561044
SMID: 143-3874-193
Condition: Good
-Sold

onan-air-cooled-5kw-genset Image

Onan Air Cooled 5KW Genset

NSN: 6115-00-456-1044
Onan air cooled 5 KW genset. Military model no MEP002A. Serial no KZ17579. 120VAC single phase, 120/240 VAC single phase, 120/208 VAC 3 phase. 1968 hours on unit. Unit turns over, appears complete. NSN 6115004561044
SMID: 143-3875-202
Condition: Good
-Sold

onan-air-cooled-10-kw-genset Image

Onan Air Cooled 10 KW Genset

NSN: 6115-00-465-1030
Onan air cooled 10 KW genset. Military model no MEP003A. Serial no RZ82390. 120VAC single phase, 120/240 VAC single phase, 120/208 VAC 3 phase. 2064 hours on unit. Missing battery gauge. Unit turns over, has not been run. NSN 6115004651030
SMID: 143-3878-381
Condition: As is
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

NSN: 6115-00-456-1044
Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. RZ06605. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 151 hrs on unit. Unit turns over, appears complete. Several available. NSN 6115004561044
SMID: 143-3880-387
Condition: Good
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. RZ00588B. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 281 hrs on unit. Unit turns over, appears complete. Several available. NSN 6115004561044
SMID: 143-3956-779
Condition: Good
-Sold

onan-air-cooled-10-kw-genset Image

Onan Air Cooled 10 KW Genset

NSN: 6115-00-465-1030
Onan Air Cooled 10 KW Genset. Military model no. MEP003A. Serial no. RZ82732. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 3886 hrs on unit. In sound enclosure, Acoustic Suppression kit ASK-10. Unit turns over, appears complete. NSN 6115004651030
SMID: 143-4048-640
Condition: As is
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

NSN: 6115-00-456-1044
Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. KZ16521. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 2351 hrs on unit. Unit turns over, appears complete. Several available. NSN 6115004561044
SMID: 143-4052-453
Condition: As is
$1,250.00

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Engine Serial no. J96061696. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 608 hrs on unit. Unit has been test run, works well, produces electricity in all phases.
SMID: 143-4056-539
Condition: Good
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

Onan air cooled 5 KW genset. Military model no MEP002A. Serial no KZ19442. 120VAC single phase, 120/240 VAC single phase, 120/208 VAC 3 phase. 1544 hours on unit. Test ran ok, NSN 6115004561044
SMID: 143-4121-051
Condition: Good
-Sold

onan-air-cooled-10-kw-genset-mep003a-3428-hrs Image

Onan Air Cooled 10 KW Genset MEP003A 3428 hrs

NSN: 6115-00-465-1030
Onan Air Cooled 10 KW Genset. Military model no. MEP003A. Serial no. RZ101115. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 3428 hrs on unit. Unit turns over, appears complete. Weight, 1220 lbs. Dimensions, L 62", W 32", Ht 37". NSN 6115004651030
SMID: 143-4401-619
Condition: Good
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. LF.AD7023. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. Unit has been test run, runs good, produces power. NSN 6115004561044. To see it run, Click here
SMID: 143-4403-931
Condition: Good
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. RZ30720. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 4448 hours. Missing phase selector switch knob. Unit turns over. Several available. NSN 6115004561044
SMID: 143-4485-635
Condition: As is
$1,000.00

onan-air-cooled-10-kw-genset Image

Onan Air Cooled 10 KW Genset

NSN: 6115-00-465-1030
Onan Air Cooled 10 KW Genset. Military model no. MEP003A. No serial no, no data tags. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 3557 hours. Motor runs, Frequency Meter pegs out, voltage Selector Switch frozen. NSN 6115004651030
SMID: 143-4489-557
Condition: As is
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

Onan Air Cooled 5 KW Genset. Military model no. MEP002A. No serial no available. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 949 hrs on unit. Unit turns over, appears complete. Several available. NSN 6115004561044
SMID: 143-4553-236
Condition: As is
-Sold

onan-air-cooled-10-kw-genset Image

Onan Air Cooled 10 KW Genset

NSN: 6115-00-465-1030
Onan Air Cooled 10 KW Genset. Military model no. MEP003A. Serial no. RZ82196. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 4648 hrs on unit. Test ran, ready to go. Weight, 1220 lbs. Dimensions, L 62", W 32", Ht 37". NSN 6115004651030
SMID: 143-4559-086
Condition: Good
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. RZ84075. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 3084 hrs. Unit turns over. Needs work, not running. NSN 6115004561044
SMID: 143-4563-271
Condition: As is
-Sold

onan-air-cooled-5-kw-genset-mep002a-mep Image

Onan Air Cooled 5 KW Genset MEP002A MEP

NSN: 6115-00-456-1044
Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. KZ19019. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 517 hrs on unit. Unit turns over, does not run. Suspect bad injection pump. appears complete. Several available. NSN 6115004561044
SMID: 144-6047-059
Condition: As is
-Sold

onan-air-cooled-5-kw-genset-mep002a Image

Onan Air Cooled 5 KW Genset MEP002A

Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Data Plate missing, engine serial no. C960599854. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 2347 hrs on unit. Unit does not run, suspect bad injection pump. Needs some work. Unit turns over. Several available. NSN 6115004561044
SMID: 144-6052-252
Condition: As is
$1,000.00

onan-air-cooled-10-kw-genset-mep003a Image

Onan Air Cooled 10 KW Genset MEP003A

NSN: 6115-00-465-1030
Onan Air Cooled 10 KW Genset. Military model no. MEP003A. Serial no. RZ01394. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 3011 hrs on unit. Unit turns over, but does not run. suspect bad injection pump. Missing DC charge gauge, AC Load Gauge. Weight, 1220 lbs. Dimensions, L 62", W 32", Ht 37".
SMID: 144-6059-734
Condition: As is
-Sold

28-vdc-military-genset-mep-0026a Image

28 VDC Military Genset MEP-0026A

NSN: 6115-00-017-8239
28 VDC Military Genset. Model no. MEP-026A. Serial no. KC68-07245. 107 Amps, 3.0 KW. 3600 RPM. Powered by Hercules Model 4A032 Gasoline Engine. Dimensions 35x24x25H, 300 lbs. NSN 6115000178239
SMID: 144-6065-076
Condition: As is
-Sold

onan-air-cooled-10-kw-genset-mep003a Image

Onan Air Cooled 10 KW Genset MEP003A.

NSN: 6115-00-465-1030
Onan air cooled 10 KW genset. Military model no MEP003A. Serial no RZ01485. 120VAC single phase, 120/240 VAC single phase, 120/208 VAC 3 phase. 2426 hours on unit. Missing starter, battery gauge, oil pressure gauge, voltage regulator, fan guard. Injection pump frozen. Front mounts bad. Unit turns over. NSN…
SMID: 144-6216-342
Condition: As is
-Sold

onan-air-cooled-10-kw-genset-mep003a Image

Onan Air Cooled 10 KW Genset MEP003A

NSN: 6115-00-465-1030
Onan air cooled 10 KW genset. Military model no MEP003A. Serial no RZ44053. 120VAC single phase, 120/240 VAC single phase, 120/208 VAC 3 phase. Missing starter, battery gauge, charge gauge, frequency gauge, hour meter, fan guard, fuel tank. Unit turns over. NSN 6115004651030
SMID: 144-6220-295
Condition: As is
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

NSN: 6115-00-456-1044
Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. KZ15184. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 1635 hrs on unit. Unit has been test run, runs good. produces powerr in all phases. NSN 6115004561044. To see this unit run, SMID: 144-6500-098
Condition: Good
-Sold

onan-air-cooled-5-kw-genset Image

Onan Air Cooled 5 KW Genset

NSN: 6115-00-456-1044
Onan Air Cooled 5 KW Genset. Military model no. MEP002A. Serial no. RZ32358. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 10 hrs on unit. Unit has been test run, runs good. produces powerr in all phases. NSN 6115004561044. to see it run, SMID: 144-6583-735
Condition: Excellent
-Sold

onan-10kw-air-cooled-genset Image

Onan 10kw Air Cooled Genset

NSN: 6115-00-465-1030
Onan 10 Kw Gen Set. Powered by Onan 4 cyl air cooled diesel. Military design, model no. MEP 003A. Serial no. RZ00552. 4035 hours on hit. 120 / 240 VAC 1 phase, 120 / 208 3 phase, phase and voltage selector switch. 24 V starter and alternator. 60 hz. Weight, 1220 lbs. Dimensions, L 62", W 32", Ht 37". Fully self…
SMID: 144-6841-278
Condition: Good
-Sold

military-model-mep004a-15-kw-genset Image

Military Model MEP004A 15 KW Genset

NSN: 6115-00-118-1241
Military Model MEP004A 15 KW Genset. Serial no. KZO3336. Unit is all original, has been test run, produces power in all phases. New alternator, 1993 hours on unit. Weight 2450 pounds, dimensions 70x36x55H. NSN 6115001181241
SMID: 144-9780-064
Condition: Good
-Sold

military-model-mep004a-15-kw-genset Image

Military Model MEP004A 15 KW Genset

NSN: 6115-00-118-1241
Military Model MEP004A 15 KW Genset. Serial no. RZ20925. Unit is all original, has been test run, produces power in all phases. 660 hours on unit. Weight 2450 pounds, dimensions 70x36x55H. NSN 6115001181241
SMID: 145-0216-431
Condition: Good
-Sold

mep003a-onan-10kw-air-cooled-genset Image

MEP003A Onan 10KW Air Cooled Genset

NSN: 6115-00-465-1030
Onan Air Cooled 10 KW Genset. Military model no. MEP003A. Serial no. RZ81400. 120 VAC single phase, 120-240 VAC single phase, 120-208 VAC 3 phase. 5807 hrs on unit. In sound enclosure, Acoustic Suppression kit ASK-10. Sound enclosure has some damage, see photos. Offered as-is. NSN 6115004651030
SMID: 148-0613-199
Condition: As is
-Sold

mep007b-100-kw-generator Image

MEP007B 100 KW Generator

NSN: 6115-01-036-6374
MEP-007B, 100 KW 3 Phase Generator Set. 12 lead re-connectable hi/low voltage. Unit serial no. BW0400. Powered by Caterpillar 3306-PCT engine. Engine serial no. 49S0416, Arrangement no. 5R3635. Hour meter reads 1721.6 total hours. Engine turns over well, unit appears complete. Made by Forster Enterprises, Inc. 6650…
SMID: 149-3930-663
Condition: Good
-Sold